空调外机怎么拆
空调外机怎么拆
How to remove the external unit of the air conditioner
1、回收制冷剂
1. Recycling refrigerant
在拆卸空调外机的时候必须将空调器中的制冷剂收集到室外机中,在拆机之前启动空调器,设置成制冷状态,等到压缩机运转5-10分钟,制冷状态正常后,拧下外机的液体管与气体管接口上的保帽。之后关闭高压管(细)的截止阀门,一分钟后管外表结露,立即关闭低压管(粗)截止阀门。迅速将空调关机,之后拔下电源插头,使用扳手拧紧保险帽,这样回收制冷剂的工作就完成了。
When disassembling the external unit of the air conditioner, the refrigerant in the air conditioner must be collected into the outdoor unit. Before disassembling the unit, start the air conditioner and set it to a refrigeration state. After the compressor runs for 5-10 minutes and the refrigeration state is normal, unscrew the protective caps on the liquid and gas pipe interfaces of the external unit. Afterwards, close the shut-off valve of the high-pressure pipe (fine). After one minute, the outer surface of the pipe will condense, and immediately close the shut-off valve of the low-pressure pipe (coarse). Quickly turn off the air conditioner, then unplug the power plug and use a wrench to tighten the safety cap. This completes the task of recovering the refrigerant.
2、室外机拆卸方法
2. Outdoor unit disassembly method
将室外机连接的螺母拧开,将准备好的密封钠子旋好护往外机连接接头的丝纹。将室外机底脚的固定螺丝松开。建议在拆卸室外机的时候,为了安全最好是用绳索吊住。捋直室外空调器的接管,堵住连接管的四个端口,防止空气中的灰尘和水份进入。之后使用塑料袋扎好、盘好。
Unscrew the nut connecting the outdoor unit and screw the prepared sealing sodium to protect the thread pattern of the external unit connection joint. Loosen the fixing screws on the foot of the outdoor unit. It is recommended to use a rope for safety when disassembling the outdoor unit. Straighten the connecting pipe of the outdoor air conditioner and block the four ports of the connecting pipe to prevent dust and water from entering the air. Afterwards, use a plastic bag to tie and tray it properly.
二、空调外机安装规范
2、 Installation Specification for Air Conditioning External Units
1、安装外机架子
1. Install the external machine rack
在空调室室外机支架的承重都是有国家标准的,所以在使用的时候是可以放心的,需要注意的是在安装的时候注意空调架子安装牢固就可以。
The load-bearing capacity of outdoor unit brackets in air conditioning rooms is in accordance with national standards, so it is safe to use them. It is important to note that the air conditioning brackets are securely installed during installation.
2、将铜管、电线与空调外机相连
2. Connect copper pipes and wires to the external unit of the air conditioner
这一步涉及到排气工作,其正确方法是将低压管连接好,之后将高压管接好后,送上1圈,打开高压阀门,听到有气体流出的丝丝声的时候,直到高压接型槽模具 一次性止血带 保定水处理设备 一次性止血带 保定空压机 北京真空泵口有氟利昂喷出,立即拧紧高压管接口,就完成排气工作。
This step involves exhaust work. The correct method is to connect the low-pressure pipe, then connect the high-pressure pipe, turn it on 1, open the high-pressure valve, and hear the faint sound of gas flowing out until there is Freon spraying out from the high-pressure interface. Tighten the high-pressure pipe interface immediately to complete the exhaust work.
3、填补墙面
3. Fill the wall
在墙面进行打孔之后是需要进行填补的,在外观上要劲量做到美观,  不能破坏室内 装修 风格。
After punching holes on the wall, it is necessary to fill them, and the appearance should be aesthetically pleasing without damaging the interior decoration style.